Review



oncentra masterplan treatment planning system  (Elekta)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Elekta oncentra masterplan treatment planning system
    Oncentra Masterplan Treatment Planning System, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+masterplan/pm40042644-37-9-8
    Average 90 stars, based on 1 article reviews
    oncentra masterplan treatment planning system - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Voxel-by-voxel correlation between radiologically radiation induced lung injury and dose after image-guided, intensity modulated radiotherapy for lung tumors.
    Article Snippet: Purpose: To correlate radiation dose to the risk of severe radiologically-evident radiation-induced lung injury (RRLI) using voxel-by-voxel analysis of the follow-up computed tomography (CT) of patients treated for lung cancer with hypofractionated helical Tomotherapy.. Methods and materials: The follow-up CT scans from 32 lung cancer patients treated with various regimens (5, 8, and 25 fractions) were registered to pre-treatment CT using deformable image registration (DIR).. The change in density was calculated for each voxel within the combined lungs minus the planning target volume (PTV).

    Article Title: Three-dimensional surface imaging in breast cancer: a new tool for clinical studies?
    Article Snippet: 3-dimensional conformal radiation therapy (3D-CRT) treatment planning was performed using the Oncentra Masterplan treatment planning system version 4.5.2 (Elekta AB, Sweden).

    Article Title: Dominant intraprostatic lesion boosting in sexual-sparing radiotherapy of prostate cancer: A planning feasibility study.
    Article Snippet: Aim: Radical radiotherapy of prostate cancer requires a relatively high dose to achieve an optimal tumor control probability and a reduced dose to the critical structures related to the sexual function (S_OARs) in order to avoid erectile dysfunction.. The aim of this study was to perform a planning feasibility analysis of a 3-level dose prescription with Simultaneous Integrated Boost (SIB) on the dominant intraprostatic lesion (DIL) and with S_OARs sparing.. Material and methods: Twelve patients with clinically localized intermediate risk prostate cancer were included.

    Article Title: Method for Automatic Selection of Parameters in Normal Tissue Complication Probability Modeling.
    Article Snippet: Radiotherapy treatments were planned using the Oncentra Masterplan (Elekta, Stockholm, Sweden) treatment planning system with either three-field 3D-CRT or with IMRT.

    Generated:

    Article Title: On the cutting edge of intensity modulated radiotherapy and simultaneous integrated boost (IMRT-SIB): The case of a patient with 8 brain metastases
    Article Snippet: .. Treatment plan was generated by Oncentra Masterplan treatment planning system and delivered by an Elekta Precise linear accelerator, equipped with a 40-leaf dynamic multileaf collimator. ..

    Article Title: Automated hybrid volumetric modulated arc therapy (HVMAT) for whole-breast irradiation with simultaneous integrated boost to lumpectomy area : A treatment planning study.
    Article Snippet: Purpose To develop an automated treatment planning approach for whole breast irradiation with simultaneous integrated boost using an automated hybrid VMAT class solution (HVMAT).. Materials andmethods Twenty-five consecutive patients with left breast cancer received 50Gy (2Gy/fraction) to the whole breast and an additional simultaneous 10Gy (2.4Gy/fraction) to the tumor cavity.. Ipsilateral lung, heart, and contralateral breast were contoured as main organs-at-risk.

    Article Title: Independent verification system for intracavitary brachytherapy based on a reference plan and statistical model.
    Article Snippet: .. Treatment plans were generated using the Oncentra MasterPlan (Elekta) treatment planning system (TPS). ..

    Computed Tomography:

    Article Title: Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom.
    Article Snippet: .. An anonymized CT scan of a typical H&N patient treated at LTHT was selected, and structures such as bone, air cavities, and brain were delineated using the Oncentra Masterplan treatment planning system (Elekta AB, Stockholm, Sweden). ..



    Similar Products

    90
    Elekta oncentra masterplan treatment planning system
    Oncentra Masterplan Treatment Planning System, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+masterplan/pm40042644-37-9-8
    Average 90 stars, based on 1 article reviews
    oncentra masterplan treatment planning system - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    86
    Elekta oncentra masterplan treatment planning system 4 3
    Oncentra Masterplan Treatment Planning System 4 3, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+planning+system+treatment/pm39900817-56-12-19
    Average 86 stars, based on 1 article reviews
    oncentra masterplan treatment planning system 4 3 - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    90
    Elekta oncentra masterplan treatment planning system version 4.3
    Oncentra Masterplan Treatment Planning System Version 4.3, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+masterplan+planning+system/pmc11664797-121-17-25
    Average 90 stars, based on 1 article reviews
    oncentra masterplan treatment planning system version 4.3 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Elekta treatment planning system oncentra masterplan
    Treatment Planning System Oncentra Masterplan, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+masterplan/pm38092967-51-6-12
    Average 90 stars, based on 1 article reviews
    treatment planning system oncentra masterplan - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Elekta treatment planning system oncentra masterplan v4.5.3
    Treatment Planning System Oncentra Masterplan V4.5.3, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+treatment+planning+system/pmc10965745-59-6-12
    Average 90 stars, based on 1 article reviews
    treatment planning system oncentra masterplan v4.5.3 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Elekta oncentra masterplan treatment planning system 4.3
    Oncentra Masterplan Treatment Planning System 4.3, supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oncentra+masterplan+treatment+planning+system/oncentra+treatment+planning+system/pm36544149-63-17-24
    Average 90 stars, based on 1 article reviews
    oncentra masterplan treatment planning system 4.3 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results